How to Use Decibel X (Free Version) to Record Construction Noise
Decibel X is one of the most accurate sound level meter apps available for smartphones, and the free version provides all the key features you need to document construction noise effectively. This guide walks you through everything from setup to evidence export.
What is Decibel X?
Decibel X (also listed as dB Meter Pro or DecibelX on some app stores) turns your phone’s microphone into a sound level meter. It gives real-time dB readings and displays averaged and peak levels.
Download links:
- iOS (iPhone/iPad): Search “Decibel X” on the App Store — look for the app by SkyPaw Co. Ltd
- Android: Search “Decibel X” on Google Play Store
The free version is fully functional for noise complaint purposes. A paid “Pro” version adds additional logging features, but you do not need it.
Step 1: Setting Up the App
When you first open Decibel X:
- Grant microphone permission – the app will ask to access your microphone; tap Allow
- Choose the correct weighting – set to dB(A) weighting. This is the standard used in UK guidance and is what Environmental Health Officers use
- Set the response time to Slow – for construction noise, Slow smooths out brief spikes and gives a more representative reading
- Check calibration – in a quiet room, your reading should show approximately 30–40 dB. If it shows significantly higher in silence, your phone’s microphone may be picking up wind noise
Step 2: Understanding the Display
- Current dB level – the large number in the centre, updating in real time
- MAX – the highest peak recorded during your current session
- MIN – the lowest level recorded
- AVG – the average level over the measurement period. This corresponds to the LAeq value used in UK assessments and is your most important figure
The AVG/LAeq value is what matters most for UK noise complaints. Councils and courts assess construction noise against LAeq levels, not momentary peaks.
Step 3: Taking a Measurement
Positioning
- Hold your phone at arm’s length pointing towards the noise source
- Do not cup your hand around the phone — this affects the microphone
- Avoid holding the phone close to your body, which can cause reflections
- If measuring indoors, stand close to (but not directly in front of) an open window
Duration
- Record for at least 60 seconds to capture a reliable average
- For intermittent noise (e.g. drilling that starts and stops), try to capture at least two full cycles of the loudest activity
- For a more formal complaint, aim for 5–10 minutes of recording to capture the true sustained level
Multiple Locations
Take readings from at least three positions:
- Inside your home (living room or bedroom — whichever is most affected)
- At your front door or doorstep
- At the boundary of your property closest to the noise source
Record the AVG reading at each position, along with the time and your exact location.
Step 4: Capturing Evidence
Taking a Screenshot
After your measurement period:
- Press the pause button to freeze the readings
- Note down the AVG, MAX, and MIN values displayed
- Take a screenshot of the screen
- The screenshot will include the readings and your phone’s timestamp visible in the notification bar
Using the History / Log Feature
In the free version, you can access a basic session history. After each measurement, note the reading in your own written log alongside the date, time, address, and type of noise. This written log, combined with your screenshots, forms a strong evidence pack.
Step 5: What the Numbers Mean
Use this rough guide when interpreting daytime AVG readings taken outside your home:
| Average Reading (LAeq) | Interpretation |
|---|---|
| Below 60 dB | Elevated background noise — unlikely to support a complaint on its own |
| 60–65 dB | Noticeable — approaching the lowest BS 5228 daytime threshold |
| 65–75 dB | Within the range where BS 5228 treats construction noise as potentially significant, depending on the area’s usual background |
| Above 75 dB | Above the highest BS 5228 daytime threshold — strong basis for a formal complaint |
| Above 85 dB | Potential hearing damage risk for prolonged exposure |
Note: At night, evenings and weekends the thresholds are far lower, so even moderate readings during those hours can support a complaint.
Step 6: Wind and Environmental Interference
Wind is the most common cause of inaccurate smartphone readings. If it is windy:
- Shield the phone microphone with your body (without covering it)
- Note the weather conditions in your written log
- Consider taking readings on a calmer day for comparison
Other interference to note: traffic passing close by, aircraft (pause and restart), and rain.
Step 7: Exporting and Sharing Your Evidence
- Create a dedicated folder on your phone called “Noise Evidence”
- Save all screenshots there, keeping notes with the date and location
- When writing to your council’s Environmental Health team, attach screenshots to your email
- Reference the readings explicitly: e.g. “On 15 March at 09:30, I recorded an average LAeq of 78 dB at the boundary of my property at [address].”
Tips for Court-Ready Evidence
- Record consistently — same positions, same app settings, multiple dates
- Accompany readings with a written log — date, time, weather, description of the noise, and your reading
- Take video on a second device simultaneously if possible, so the noise and the app screen are captured together
- Note the phone model — some models are more accurate than others
- Keep raw screenshots unedited — do not crop or alter the images
Limitations of Smartphone Measurements
- Smartphone microphones are not Class 1 or Class 2 sound level meters as defined by IEC 61672, so councils and courts may treat readings as indicative rather than conclusive
- For the strongest evidence, consider an independent acoustic consultant if your complaint is serious
- That said, consistent smartphone readings from multiple sessions significantly strengthen a complaint and are widely accepted as supporting evidence by Environmental Health Officers
General guidance, not legal advice. Supported by Hushtec, a New Zealand manufacturer of temporary acoustic barriers with a UK manufacturing site in Wakefield, West Yorkshire, where its Performance and Premium panels are made.